Hospital Elevator yang kami tawarkan terdapat beberapa kategori standar yang dibedakan berdasarkan dari beban maksimal yang dibutuhkan dan ukuran ruangan. Dikarenakan penumpang yang diakomodasi oleh lift jenis ini diasumsi sebagai pasien, maka Hospital Elevator memiliki tingkat keamanan yang lebih tinggi dan sistem penggerak dan pengereman yang lebih halus sehingga tingkat kenyamanan penumpang lebih terjaga.
Beberapa fitur standar yang sudah melekat pada produk Hospital Elevator kami antara lain:
STANDARD FEATURES for HOSPITAL ELEVATOR |
|
Door Safety Edge |
When a passenger or an object touch one of these safety edges the elevator will stop and the door at the point of contact will reopen immediately |
Overload Device |
The Car Overload Device prevents the elevator doors from closing while a lift is loaded beyond its rated load capacity and simultaneously sounds a warning buzzer as well as providing visual indication. |
Emergency Exit |
When trapped inside the elevator, passenger can be push out the emergency exit in the top ceiling and the elevator will be shut off |
Exhaust fan |
For the ventilation inside the car on the top of ceiling |
Light |
Lightning inside the car on the top of ceiling |
Interphone |
When the alarm/emergency signal button inside the car is pressed, the elevator telephone automatically establishes a connection with the alarm centre or a pre-programmed alarm recipient. At the same time, the position of the emergency call device is communicated |
Emergency Car Lighting |
Car lighting that turns on automatically upon power failure to illuminate the inside of a car using a battery for Emergency Car Lighting. |
Out of Service switch in Car |
The Elevator can be use manual for maintenance |
Top of Car Insepction Unit |
Allows technicians and inspectors to safely ride on top of the lift by giving them total control of the lift. The lift can be driven independently at slow speed to allow inspection and service |
Automatic Parking |
When service of elevator is stopped, any floor can be selected to park elevator (main floor and upper floor). This allowing more efficient service to future hall calls |
Emergency Exit Ladder |
When trapped inside the elevator, passenger can going to emergency exit in the top of ceiling immediately using ladder inside the car |
Car Light and Fan automatic shut off |
Elevator can be installed an energy saving features with automatically switch off the internal lighting and exhaust fan when calls are registeres after predetermined period of time |
Door Hold Open Feature |
Opens the door, reverses the door, and keeps the door open for a specified adjustable door hold time |
OPTIONAL FEATURES for HOSPITAL ELEVATOR |
|
Features |
Descriptions |
Automatic Rescue Devices (ARD) |
During the normal power failure, the ARD converts stores energy from it bank of rechargeable batteries to the nearest floor and open the door to let passenger out |
Fireman Emergency Operation |
Fire Emergency Operations that is started in case of fire Operation Switch located in a hall. After the car has arrived at the Return Floor, the car can be used exclusively for firefighting and rescue operations |
Car Arrival Chime |
A chime to indicate that a car will soon arrive to inform waiting passengers at each floor |
Optical Doors Safety Device |
A safety device to prevent passengers from being caught by the doors, using infrared that detect passengers around the car entrance. The doors reverse and open if a passenger or baggage in a hall is detected during door closing |
Car Call Canceling |
A function where Car Calls that have been made for bypassed floors and are still effective when the car arrives at the last floor are regarded as mistakes and collectively cancelled |
OPTIONAL FEATURES for HOSPITAL ELEVATOR |
|
Operating by Emergency Power (Source – Automatic) |
Emergency Operation where elevators are operated with an emergency power source during power failure using the building generator. When the elevators car arrives at the specified floor, the door will open to allow passenger out and then elevator will shut down |
Non-Service to specific Floors |
A switch located in the Service Cabinet of the Car Operating Panel, with which Non-Service to Specific Floors can be set for any desired floors. This function is automatically deactivated during Emergency Operations |
Duplex Control |
Two elevators receive external calling signal at the same time, and unified management is carried out by system to raise operation efficiency of elevator. |
Elevator Group Control System |
The control systems that manage systematically three or more elevators in order to efficiently transport the passengers’ artificial intelligence and fuzzy logic. Most of the EGCS’s have used the hall call assignment method to assign elevators in response to passenger’s calls |
Control Function of ID Card |
For special requirement, the ID card can be used to identify the status of passenger, and also, it can be used for timing charge |
Hall Lantern |
Hall Lantern on each floor will flash to indicated elevator car arrival and service direction to passengers waiting at the elevator lobby |
Door Nudging Feature |
A function where doors close automatically along with a warning voice and a sound when the doors have been kept from closing for a certain length of time |
Supervisory Panel |
This is a monitoring panel located in the security room that displays the status of all the elevators operating in the building including flooring location, travelling direction, in/out of service etc. |